NOTE: The Advanced Pneumatic Tube System was sunset in Q3 of 2024. For new pneumatics offerings, click here.
Simple to install and maintain, the Bavis Advanced Pneumatic Tube System raises the bar for drive-thru solutions for banks and financial services organizations. Building on the same great features and functions of the Basic Pneumatic Tube System, the advanced solution includes a redundant shut-off system (resulting in minimized blower run time, less down time and extended motor life) and powder coated aluminum vertical-enclosures available in custom colors to provide an attractive rust-free finish.
Ratings | UL-listed |
Materials used | PVC tubing, durable plastic carrier |
Finish options | Powder-coated aluminum (texture beige) |
Unit Max Ht. | 25 ft., (deduct 2 ft. of max horizontal run for every foot of vertical height above 16 ft.) |
Unit max extension / horizontal run length (varies depending on number of turns) | 120 ft. at 16 ft. horizontal elevation with support every 5 to 10 ft. For longer runs, add additional blowers and AC circuit. |
Carrier dimensions/capacity | Carrier Interior dimensions: 1-5/8" R x 2-5/8" W x 9-3/8" L appx. 67 cu. in. |
Required clearances (wall openings, overhang) | Clearance: Verticals = 12" x 12", Horizontal = 6" dia. on path centerline Rec. Canopy Overhange = 8 ft. at 12 ft. elevation |
Power requirements | (1) 110-120Vac 1PH 20 AMP (with connection points at the top of both verticals) |
Audio included | Exterior components (mic, speaker, call button) |
Optional accessories | Internal audio options, video, vehicle detectors, steel turns and horizontal tubes, photo eye blower stops, additional blowers |
Model numbers | 23000992 |